heat duty for 5 tons water boiler

HTP - Water and Space Heating

Space Heating. HTP's space heating boilers provide ultimate comfort and the best overall efficiency ratings while keeping maintenance and operating costs to a minimum. With a HTP high efficiency boiler you can achieve the heat your family or business needs while also saving money and energy.

Electrical Rules and Calculations for Air-Conditioning

This is the first Article in our new Course HVAC-2: Electrical Rules and Calculations for Air-Conditioning Systems, which will list, explain, and discuss with examples all the topics covering the Electrical Rules and Calculations for Air-Conditioning Systems which will include but not limited to the following points:. Introduction for Air-Conditioning Systems types,

Heat strip sizing - HVAC-Talk: Heating, Air

So with 5kw I can run 700-900 cfm and don't notice the sound difference from heating to cooling with my (2.5) ton heat pump as per manual D my duct system will handle 900-1000 cfm. This topic brings up something that I learned in a Trane training class with the Hyperion air handler that with there heat packs you need to move more air for the

PDF WATER-TO-WATER SYSTEMS - Climate Master

can be used for radiant fl oor heating, snow/ice melt, chilled water for fan coils, potable hot water generation (with hot water generator option), hot/chilled water for make-up air, and many other types of HVAC applications. Available in sizes 036 [8.7 kW], 060 [13.5 kW] and 120 [26.9 kW]

Calculating Cooling Loads - Engineering ToolBox

A water-chiller refrigeration ton is defined as: 1 Refrigeration Ton (RT) = 1 TONS cond = 12000 Btu/h = 200 Btu/min = 3025.9 k Calories/h = 12661 kJ/h = 3.517 kW. 1 kW = 0.2843 Refrigeration Ton (RT) A ton is the amount of heat removed by an air conditioning system that would melt 1 ton (2000 lbs.) of ice in 24 hours.

Q: How much water does an open-loop geothermal heat pump

For instance, one manufacturer says that if the ground water temperature is 55°F, the company's 3-ton (36,000 Btu) unit requires a flow rate of 2.5 to 3 gpm/ton. If the water temperature is 50°F, the required flow rate for this equipment in the heating mode grows to 5 gpm, while at forty-five degrees water must flow at the rate of 10 gpm.

Product List | Velocity Boiler Works

The Freeport 2 FWZ Series boiler is a 3-pass cast-iron, oil-fired, hot water boiler. The Freeport 2 FWZ is designed for installation with a standard chimney. This boiler is available in heating capacities from 73 to 197 MBH and all models of the Freeport 2 FWZ boiler are ENERGY STAR® qualified. See details

Belan BFX060 - Vertical 5 TON Geothermal Water Source Heat

HPX 5 Ton Geothermal Heat Pump (2 Stage + Quiet Package + Air Inlet (Right) + Domestic Hot Water) 4.0 out of 5 stars 1. 1 offer from $4,797.99. FIRST COMPANY"Scratch & Dent" Central Air Conditioner 4 Ton Commercial Package Unit - Geothermal Heat Pump WSVC048CELHFT ACC-6811

How to calculate the heat duty for heat exchangers

Qg - is the gas heat duty or heat transfer rate, Btu/hr or kW. Qo - is the oil heat duty or heat transfer rate, Btu/hr or kW. Qw - is the water heat duty or heat transfer rate, Btu/hr or kW _____ Here is a free heat duty calculator that I built - you can read more about it from the webbusterz engineering software using the link below:

RLHL (10 Ton) | Ruud Commercial Package Air Conditioners

H2AC™ Package Unit featuring eSync™ Integration Technology includes water circulation pump, refrigerant-to-water heat exchanger, and eSync Integration Technology control board for heat recovery during air conditioning mode to preheat potable water; R-410A HFC refrigerant. Complete factory charged, wired and run tested. Scroll compressors with internal line break overload and high-pressure

PDF EPA Emissions Rules for Boilers - aeeohio.com

EPA Emissions Rules for Boilers On March 21, 2011, the U.S. Environmental Protection Agency (EPA) published three rules regarding air A "Major Source" facility emits 10 or more tons per year of any single air toxic or 25 tons or heat boilers and boilers used for research purposes. A list of exclusions can be found on page 33.

Boiler Brands - Best Boiler Brand Names - Manufacturers

Superior Boiler is located in Hutchinson, Kansas. Superior manufacturers high-efficiency condensing boilers, and boiler equipment for hot water, process steam, and waste water recovery. including industrial and commercial heat exchangers & preheaters, cast iron boilers, fire tube boilers & water tube boiler systems.

Air-Source Heat Pumps | Department of Energy

The heat pump is connected to a large, heavily insulated tank of water that the heat pump heats or cools, depending on the season of the year. Most systems will use a fan coil with ducts, using the stored water to heat or cool the air and distribute it to the house.

AAON Heating and Cooling Products

Water-Source Heat Pumps. For over 15 years AAON has manufactured Water-Source Heat Pump (WSHP) Rooftop Units, Vertical Self-Contained Units, and Modular Air Handling Units with capacities ranging from 2-230 tons. AAON offers all of these units with mass customization or the ability to configure the features and options of the unit at the

Heating & Air Conditioning HVAC Installation - Lowe's

From furnace installation and heating system installation to air conditioning installation and central air installation, Lowe's has all your HVAC installation needs covered. Lowe's will coordinate with independent air conditioner installation professionals to make installing central air a breeze.

5 Ton Heat Pumps - eComfort

5 Ton Heat Pumps Quick Search Select Product Type Boilers - Hot Water Boilers - Steam Central Air Conditioners Central Air Packages Central Heat Pumps Dehumidifiers Electric Radiant Floor Heating Energy Recovery Ventilators Fans Gas Furnaces Heat Recovery Ventilators Humidifiers Mini Split Systems (Ductless) PTAC Units Radiators Shower Systems

PDF CHAPTER Utilities and Energy Efficient Design 3

106 CHAPTER 3 Utilities and Energy Efficient Design Note that if we had decided to carry out all of the heating in the radiant section only, then the fuel required would have been 4/0.6=6.67 MW and the annual cost of heating would increase to $582,600 unless we could

Water Source Heat Pump| Axiom Water-to-Water 5 to 20 tons

The water-to-water heat pump is an Axiom™ 5, 10 and 20 ton system. Similar to a small reverse cycle chiller, a water-to-water heat pump contains a source-side water-to-refrigerant heat exchanger, and a load-side water-to-refrigerant heat exchanger.The source for the water-to-water heat pump is typically connected to a boiler/cooling tower, or a ground-source loop system.

Heat Pump System Costs - Home repair

Capacity or Size of the Heat Pump (BTU/Ton) Heat pumps range in capacity from 1.5 to 5.0 tons. That is 18,000 to 60,000 BTUs. You don't have an option here. The HVAC technician will do a load calculation to determine the heating and cooling requirement for your home, that is, the capacity of the heat pump needed.

Air Conditioners Portable - 1 to 5 Ton - Herc Rentals

In general, a one-ton unit cools approximately 400 sq. ft. of space, while a 5-ton unit can cool a 4,000 sq. ft. of space. These units require proper venting and most include both heating and cooling to maintain a constant temperature day or night.

Buy Amana Split Systems | Air Conditioning | Heat Pumps

Water Source Heat Pumps. Copper (15) Cupro-Nickel (20) Portable AC Systems. Air Conditioning (32) Heat Pump (10) Packaged Terminal Systems. Electric Heat (15) 1.5 Ton 15 Seer Amana Heat Pump System. Model: ASZ140181 - CAPF3636B6 - MBVC1200AA-1 - TX2N4. Call for Details. Add to Compare.

PDF Applications Engineering Manual - Trane

2 Water-Source and Ground-Source Heat Pump Systems SYS-APM010-EN Overview of a Water-Source Heat Pump System Figure 2. Primary components of a water-source heat pump system Typically, outdoor air required for venti lation is conditioned and delivered by a separate, dedicated outdoor-air system.

Gas & Electric Water Boilers | Commercial Boilers for Hot

Reputations aren't built overnight. The A. O. Smith story started in 1936 when we produced our first water heater. Since then, plumbing professionals have been relying on us more than any other manufacturer because we consistently provide new and improved hot water solutions for their customers. Through an inspired blend of innovation, experience, teamwork and technology, we have once again

Water Circulation Pumps - Boiler

Maximum Head means the total rise (or drop) from the pump to heat exchanger PLUS the distance one way times .08. For example, a 100 foot run would equal 8 head feet (100 x .08) PLUS any RISE in elevation and remember you need to add the number of feet deep any insulated Pex pipe is buried X TWO

PDF BOILER SELECTION CONSIDERATIONS - Cleaver-Brooks

Boiler Selection Considerations 5 Industrial Watertube Boilers The industrial watertube boiler typically produces steam or hot water primarily for industrial process applications, and is used less frequently for heating applications. In the watertube design, tubes contain steam and/or water and the products of combustion pass around the tubes.

PDF Commonly Used HVAC Formulae and Conversions

Commonly Used HVAC Formulae and Conversions Air Side Q Total = CFM x (h i ‐ h f) x 4.5 Btuh Q Sensible = CFM x (t i ‐ t f) x 1.085 Btuh Q Latent = CFM x (Gr i ‐ Gr f) x .068 Btuh Humidification = CFM x (Gr f‐Gr i) / 1,555 lbs/hr CFM = l/s x 2.12 Air Pressure Drop (in. wg) = Pa / 249 Water Side Q = USGPM

7 Tips to Get More from Mini-Split Heat Pumps in Cold Climates

So far this winter, from October 2012, to March 23, 2013, the usage has been 1,501 kWh. I have a 5.4 kW PV array that supplies about 200% of my electrical consumption, including that of the heat pump, so the heating system is very "green."

Buy Boiler Units Online | Shop Laars Boilers | HVACDirect.com

Buy Boiler Furnaces Online with HVACDirect.com! Are you shopping for a new boiler furnace? Check out our selection of boilers and buy your furnace online. These boiler systems have the BTU power that you need for keeping you and your family warm & toasty during even the coldest of winter storms.

Heat Pump | Heat Pump System | Electric Heat Pump | Carrier

Carrier split system heat pumps are a smart alternative to an air conditioner, offering heating, cooling, dehumidifying, and more. Versatile, energy efficient electric heat pumps are an effective solution to your heating and cooling needs. Learn more about Carrier residential heat pumps.

PDF Wood Pellets for Power and Heat - Wood Pellet Association

residential and commercial/institutional heat and hot water energy consumption. 100% conversion of all non-gas heat and hot water represents 60 millions of wood pellets annually. We will offer evidence. So 100% conversion is not achievable? How about just 5% conversion? That represents 3 million tonnes annually.

PDF Tranquility 27™ Two-stage (Tt) Series

ClimateMaster Water-Source Heating and Cooling Systems CLIMATEMASTER WATER-SOURCE HEAT PUMPS Tranquility 27™ Two-Stage (TT) Series Rev.: 05/23/07D TT 4 Air Flow Water Flow Ext Static Pressure Water Pressure Drop Airflow (L/s) = CFM x 0.472 Water Flow (L/s) = gpm x 0.0631 ESP (Pa) = ESP (in of wg) x 249 PD (kPa) = PD (ft of hd) x 2.99

How do heat exchangers work? - Explain that Stuff

Hot water is piped through it from a gas central heating boiler, giving up some of its heat to the air in the room in the process and returning to the boiler for more. This is a sort of heat exchanger because the heat from one fluid (the hot water in the pipe) is being given to another fluid (the cold air in the room) without the two fluids mixing.

Amazon.com : ANDRIMAX Immersion Heater for Boiling Bath

Make sure this fits by entering your model number. ♥♥【HEATING WATER IN MINUTES】 - Submersible electric heater makes water heating more efficiency and boil 5 gallon of the water in minutes, all you need to do is just put the heater in to the water then connect the 120V power supply, easy to use.

Buy Water Source Heat Pumps Online | Wholesale Prices

This gives water-source heat pump projects a quick financial payback. WSHP's are ideal for high-rises, condominiums, apartment buildings, offices, schools and much more. Water source heat pumps have a much longer life span than traditional central air conditioning and heating split systems do, and they are much easier to service and maintain.

WaterFurnace Geothermal Systems » Eden Energy Equipment

5 Series Water to Water Hydronic (502W12) The geothermal equivalent to a Boiler. The 5 series water to water is a compact hydronic geothermal system that is perfect for radiant floor, spa, pools, fan coils. This unit is specifically engineered to produce up to 150 degree hot water for your high temp hydronic needs. High temperature hydronic.

Boiler Capacity - Engineering ToolBox

Horsepower (hp) can be converted into lbs of steam by multiplying hp with 34.5. Example - Boiler Horsepower to lbs of Steam Conversion. 200 hp x 34.5 = 6900 lbs of steam per hour. Lbs of steam can be converted to hp by dividing lbs steam per hour by 34.5. Example - Lbs of Steam to Boiler Horsepower Conversion. 5000 lbs of steam / 34.5 = 145 hp

Commercial Packaged Rooftop Units | YORK®

Packaged Rooftop Units Superior Efficiency, Greater Control, Unmatched Comfort. With a 3-150 ton capacity range and efficiency ratings as high as 17.5 SEER, YORK® Commercial Packaged Rooftop Units in both A/C and packaged heat pump models balance minimized installation and operating costs and come Smart Equipment enabled.

Contactors for Air Conditioners and Heat Pumps

Below is a (2) Pole Contactor: The large terminal screws always have 230 Volts of power applied to the (2) lower terminals in the picture. Your compressor and fan motor wire leads are connected to the (2) top terminals in the picture.. As your thermostat calls for heating or cooling the 24 volt coil "Pulls" in through a magnetic action, making contact from the always powered 230 volt side of

PDF The World's Most Efficient Chiller Heat Pump

Can serve as low-cost primary heat when used with an existing boiler heating system. Perfect for radiant floor heating. Dramatically reduces heating costs for users of electric, propane or oil fired boiler systems. Modular - Stackable The CX34 can be configured with up to 3 outdoor units to create systems up to 6 Tons Cooling/8.5 Tons Heating

Calculating BTU Transfer Using The Water Formula

Here's an example, using 100% water for simplicity. Lets say we know the flow rate is 5 GPM and the entering temperature of a system (solar, boiler, heat recovery, whatever) is 120 and the leaving temperature is 125. So, 5 degrees are added at 5 GPM. The BTU of this transfer is 5 x 5 x 500 or 12,500 BTU per hour.